PROFI Control Panel (JA-63K‎)

PROFI Control Panel (JA-63K‎)

  • Brand: JABLOTRON ALARM A.S
  • Country of Origin: Germany
  • Category: Intrusion Alarm System, PROFI
  • Model: JA-63KRX
  • Download Catalog
  • Overview
  • Technical specification

The JA-63K main board has 4 hard-wired inputs with programmable triggering (NC, balanced or double balanced) and programmable reactions.

   Model JA-63KR (equipped with the \"R\" radio communicating module) has 16 wireless zones. Up to two JA-60 detectors can enrolled into each zone (totally 32 as a maximum). In total model 63KR has 20 zones (4 wired and 16 wireless). Up to 8 wireless controllers (remote controls or wireless keypads), a JA-60A wireless siren and unlimited number of UC family wireless output modules can be enrolled as well. If more zones are required, another JA-6x control panel can be enrolled as a subsystem (Master & Slave architecture). The master control panel receives information from the sub control panel and it can also arm and disarm the subsystem panel.

   Telephone module \"X\" can communicate with a Monitoring Station, send two voice messages, send five SMS messages via SMS server (or dial a numeric Pager) or. It can also communicate with a remote PC (using ComLink SW and a JA-60U modem).

   Operation and programming is possible via the JA-60E keypad (either directly wired to the control panel or remotely using JA-60U modem). The control panel equipped with a radio module (63KR, 63KRX) can also be programmed and operated by a JA-60F wireless keypad and can also be operated by RC-11 or RC-22 remote controls or by a JA-60D wireless keypad. Operation and programming is also possible via a PC using ComLink SW (locally or remotely via JA-60U modem).

Electrical

Power

230 VAC, max 0.1 A, supervised, class II

Backup battery

12 V, from 1.3 or 2.6 Ah, normal life time 5 years

Backup power output

13VDC, the max. Permanent current is 0.4 or 1.2 A for max. 15 min (1 cycle per hour), self-consumption of the control panel is 30mA

Hard-wired inputs

4 input zones, selectable triggering: NC, EOL resistor or Double EOL resistor

Zone reactions

selectable: instant, delayed, panic, fire, 24 hour, next delayed

Wireless zones

16 zones (2 detectors can be enrolled to each = up to 32 detectors totally)

Frequency

433.92 MHz; digital hopping code; supervised communication

Keypads

Max. 4 wired JA-60E keypads, max. 8 JA-60F wireless keypads** or RC-11 or JA-60D remote controllers **

Access codes

Master code and 14 user codes. When system is split, codes, detectors and remote controls can be addressed to particular sectors

Wired outputs

Alarm relay dry contacts 1A/60V; programmable outputs PgX & PgY (Chime, Fire, Arm, Panic, Alarm, Door, Home, AC failure), siren output (12 V, 0.7 A)

Wireless outputs

control panel transmits signals for siren and PgX, PgY data for UC-2xx receivers

Events memory

127 most recent events including date, time and detailed specification

Telephone communicator

module 65X: digital communication to a monitoring station, 5 SMS messages or Pager dialing, 2 voice messages, modem communication with a remote PC (ComLink SW + JA-60U modem), remote keypad access with JA-60E and JA-60U

Monitoring station formats

Contact ID, Ademco, Telemax, Franklin, Radionics, SurGard, DTMF2300, (198 reports codes)

* control panel equipped with telephone dialer JA-65X
* wireless control panel (JA-63KR, JA-63KRX)

Environmental

Operating temperature

-10°C to 40° C

Operating humidity

max 80 %

Working environment

indoor use (class II, EN 50131-1)

Immunity

Electrostatic discharge

8 kV

RF immunity

30 V / m

Physical

Housing

plastic box with built-in power supply

Dimensions

see diagram bellow

Standards

Complies with

EN 50131-1 (Grade 2), EN 50131-6, EN 300220, ETS 300 683, EN 50136, ETS 300001, TBR 21